DS-PDBG8-EG2

An indoor wired acoustic detector for glass-break enquiries. Check the glazing, pane size, room acoustics and alarm-panel wiring before selection.

Hikvision · Full reference: DS-PDBG8-EG2

Choose quantity

Manufacturer reference

Manufacturer details describe the cited version. Confirm the exact unit and intended system.

Detection & glazing

Detection method
Acoustic sensing for glass break detection.
Coverage reference
Up to 8 m over a 120° detection angle; manufacturer reference, not a guaranteed room coverage.
Sensitivity adjustment
Potentiometer adjustment.
Glass thickness reference
2.4-6.4 mm for the manufacturer-listed glass conditions.
Glass size reference
Manufacturer-listed pane sizes: 0.3 × 0.3 m to 3 × 3 m.
Digital processing
Supported in the cited specification.

Wiring & power

Tamper reference
Front tamper protection.
Alarm output
Normally closed (NC); confirm the alarm-panel wiring and load limits.
Transmission method
Wired.
Input power
9-16 V DC; typical voltage 12 V.
Current reference
Maximum and quiescent current are both listed as 25 mA at 12 V DC.
EOL resistor options
Selectable alarm resistance: 1K, 2K2, 4K7, 5K6 and 6K8; match the panel's specified EOL wiring.
LED reference
Red: high-frequency trigger; green: low-frequency trigger; blue: alarm.

Mounting & environment

Installation reference
Indoor application; wall or ceiling mounting.
Operating temperature
-10 to 55 °C.
Operating humidity
10-90%; confirm site conditions.
Body dimensions
38.8 × 107 × 22.5 mm (W × H × D).
Device weight
49.5 g; not a shipping-package weight.

Selection notes

  • Confirm the supplied hardware, compatible panel and installation against this manufacturer reference.
  • ISD confirms supply, actual package, price, stock, lead time and local warranty separately.
  • Keep the complete DS-PDBG8-EG2 model. The -WB version is a separate wireless reference.
  • The range, angle, thickness and pane-size figures do not confirm every glazing type or room. Provide glass construction, size, curtains or obstructions and the panel model for checking.
  • This is a wired acoustic detector, not a PIR movement detector. NC output and EOL options do not establish universal panel compatibility or output load rating.
  • The cited document does not establish outdoor suitability. Confirm the actual environment and installation with the technical team.
  • No printed revision is identified. A filename date is not a hardware or document revision.

Official documents

Manufacturer source checked 2026-10-15. The supplied unit and local terms require confirmation.