DS-K2604T

DS-K2604T is listed as a four-door access controller. Its enclosure and main-board references have different inputs and dimensions; confirm the supplied form factor, readers and lock requirements before choosing quantities.

Hikvision · Full reference: DS-K2604T

Choose quantity

Manufacturer reference

Manufacturer details describe the cited version. Confirm the exact unit and intended system.

Door and reader interfaces

Device class
Four-Door Access Controller
Door control reference
4 doors in this DS-K2604T reference; readers, locks and accessories need separate confirmation.
Reader interface counts
8 RS-485 reader references and 4 Wiegand reader references; not a guarantee of 12 simultaneous readers.
Door contact inputs
4
Exit-button inputs
4
Alarm inputs
4
Case inputs
8 case inputs as printed; confirm exact I/O function and wiring.
Tamper input reference
1 tamper alarm input
Fire-alarm input reference
1 fire-alarm input; this alone is not a compliant emergency-release design.
Lock relay outputs
4 lock relay outputs; count is not a contact/load rating or lock-power supply.
Alarm relay outputs
4

Capacity and access functions

Processor
32-bit processor
Card capacity
Up to 100,000 cards, including 97,000 non-visitor cards and 3,000 visitor cards.
Event capacity
Up to 300,000 card-presenting event records.
Card-number length
Maximum length 20 in the card-number reference; confirm the exact card format.
Communication references
TCP/IP, RS-485 and Wiegand W26/W34; features also name EHome5.0, ISAPI and OSDP. Verify exact reader/protocol/firmware support.
Offline reference
Offline event storage and insufficient-storage warnings are listed; data is retained when powered off.
Access-control functions
Multi-door interlock, anti-passback, multiple authentications, first-card opening, super-card and super-password functions are listed.
Cross-controller anti-passback
Card-based operation requires RS-485 reader wiring. Network-based operation requires working server/device communication; the selected server reference stores up to 5,000 users’ records.
Alarm-function references
Reader tamper, unsecured/forced/timeout door, duress, blocklist and repeated illegal-card alarms are listed; verify sensors and I/O configuration.
Linkage reference
I/O and event linkage
Password-group reference
500 password groups in card-or-password authentication mode.
Clock and time-zone reference
Built-in clock, automatic/manual synchronization and time-zone settings are listed.

Power and physical profiles

Enclosure AC input reference
100–240 V AC in the enclosure reference, not the bare-board input.
Main-board DC input reference
12 V DC for the main-board profile, not an AC input.
Loaded consumption reference
Up to 100 W with load in the DS-K2604T reference; not a relay contact rating.
Unloaded consumption reference
Up to 4 W without load; not loaded consumption.
Main-board dimensions reference
236 × 185 × 37 mm, main-board only; do not use as the enclosure footprint.
Working temperature
−20–65 °C in the reference configuration.
Working humidity
10–90%, non-condensing

Selection notes

  • DS-K2604T four-door model only; this Algeria regional enclosure reference is not a Malaysia supply or package confirmation.
  • Common family entries apply only to DS-K2601T, DS-K2602T and DS-K2604T in this Algeria regional enclosure reference; confirm the supplied profile.
  • Main-board profile only; confirm the supplied form factor before wiring or ordering.
  • Reader counts are per stated interface reference, not guaranteed concurrent operation. Check reader protocol, power, topology, firmware and relay load.
  • Enclosure AC input and main-board DC input describe different physical profiles, not interchangeable wiring instructions.
  • No local kit, battery, enclosure, locks, readers, stock, price, delivery or warranty is confirmed.

Official documents

Manufacturer source checked 2026-10-20. The supplied unit and local terms require confirmation.