DS-1LN6UEC0
Hikvision DS-1LN6UEC0 is Cat 6 U/UTP cable with a PVC sheath and solid bare-copper conductors. The September 2024 specification lists a 305 ± 1.5 m roll and 24 AWG conductors. Transmission results below retain the manufacturer test length and conditions.
Hikvision · Full reference: DS-1LN6UEC0
Choose quantityManufacturer reference
Manufacturer details describe the cited version. Confirm the exact unit and intended system.
Cable Construction
- Shielding
- U/UTP
- Category
- Cat 6
- Reference Standards
- ISO/IEC 11801; ANSI/TIA-568.2-D; RoHS 2.0
- Fire Resistance
- No
- Conductor Material
- Solid bare copper; 99.95%
- Conductor Diameter
- 0.53 ± 0.01 mm; 24 AWG
- Insulation Material
- HDPE
- Insulation Diameter
- 0.93 ± 0.05 mm
- Sheath Thickness
- 0.50 ± 0.05 mm
- Sheath Diameter
- 5.50 ± 0.50 mm
- Sheath Material
- PVC
- Sheath Colours
- Grey or orange; confirm ordered colour
- Rip Cord
- Yes
- Separator
- Yes
Electrical and Material Tests
- Sheath before Aging
- Tensile strength ≥ 13.5 MPa; elongation ≥ 150%
- Sheath Aging Test Condition
- 100 °C × 24 h × 10 d, as printed
- Sheath after Aging
- Tensile strength ≥ 12.5 MPa; elongation ≥ 125%
- Cold Bend Test
- −20 ± 2 °C for 4 h; 8 × cable O.D.; no visible cracks
- Impedance at 20 °C
- 100 ± 15 Ω over 1–250 MHz
- Delay Skew at 20 °C
- ≤ 45 ns/100 m over 1–250 MHz
- DC Resistance at 20 °C
- ≤ 9.38 Ω/100 m
- DC Conductor Resistance Unbalance at 20 °C
- ≤ 4.0%
Packaging and Conditions
- Package Dimensions
- 390 × 390 × 220 mm
- Weight
- 11.9 ± 0.5 kg
- Cable Length
- 305 ± 1.5 m
- Ambient Temperature
- −20 to 70 °C
- Operating Voltage
- 57 V
Manufacturer Link Tests
- Manufacturer Permanent Link Test
- 90 m Fluke permanent link test while operating continuously at 50 °C
- Manufacturer Channel Test
- 100 m Fluke channel test under continuous 57 V / 1 A DC (PoE) loading
Transmission Performance at 100 m (ATT at 20 °C)
- Test at 1 MHz (100 m)
- ATT ≤ 2.03 dB; RL ≥ 20.0 dB; NEXT ≥ 74.3 dB; PS NEXT ≥ 72.3 dB; EL FEXT ≥ 67.8 dB; PS EL FEXT ≥ 64.8 dB; Phase delay ≤ 570 ns
- Test at 4 MHz (100 m)
- ATT ≤ 3.78 dB; RL ≥ 23.0 dB; NEXT ≥ 65.3 dB; PS NEXT ≥ 63.3 dB; EL FEXT ≥ 55.8 dB; PS EL FEXT ≥ 52.8 dB; Phase delay ≤ 552 ns
- Test at 8 MHz (100 m)
- ATT ≤ 5.32 dB; RL ≥ 24.5 dB; NEXT ≥ 60.8 dB; PS NEXT ≥ 58.8 dB; EL FEXT ≥ 49.7 dB; PS EL FEXT ≥ 46.7 dB; Phase delay ≤ 547 ns
- Test at 10 MHz (100 m)
- ATT ≤ 5.95 dB; RL ≥ 25.0 dB; NEXT ≥ 59.3 dB; PS NEXT ≥ 57.3 dB; EL FEXT ≥ 47.8 dB; PS EL FEXT ≥ 44.8 dB; Phase delay ≤ 545 ns
- Test at 16 MHz (100 m)
- ATT ≤ 7.55 dB; RL ≥ 25.0 dB; NEXT ≥ 56.2 dB; PS NEXT ≥ 54.2 dB; EL FEXT ≥ 43.7 dB; PS EL FEXT ≥ 40.7 dB; Phase delay ≤ 543 ns
- Test at 20 MHz (100 m)
- ATT ≤ 8.47 dB; RL ≥ 25.0 dB; NEXT ≥ 54.8 dB; PS NEXT ≥ 52.8 dB; EL FEXT ≥ 41.8 dB; PS EL FEXT ≥ 38.8 dB; Phase delay ≤ 542 ns
- Test at 25 MHz (100 m)
- ATT ≤ 9.51 dB; RL ≥ 24.3 dB; NEXT ≥ 53.3 dB; PS NEXT ≥ 51.3 dB; EL FEXT ≥ 39.8 dB; PS EL FEXT ≥ 36.8 dB; Phase delay ≤ 541 ns
- Test at 31.25 MHz (100 m)
- ATT ≤ 10.67 dB; RL ≥ 23.6 dB; NEXT ≥ 51.9 dB; PS NEXT ≥ 49.9 dB; EL FEXT ≥ 37.9 dB; PS EL FEXT ≥ 34.9 dB; Phase delay ≤ 540 ns
- Test at 62.5 MHz (100 m)
- ATT ≤ 15.38 dB; RL ≥ 21.5 dB; NEXT ≥ 47.7 dB; PS NEXT ≥ 45.4 dB; EL FEXT ≥ 31.9 dB; PS EL FEXT ≥ 28.9 dB; Phase delay ≤ 539 ns
- Test at 100 MHz (100 m)
- ATT ≤ 19.80 dB; RL ≥ 20.1 dB; NEXT ≥ 44.3 dB; PS NEXT ≥ 42.3 dB; EL FEXT ≥ 27.8 dB; PS EL FEXT ≥ 24.8 dB; Phase delay ≤ 538 ns
- Test at 200 MHz (100 m)
- ATT ≤ 28.98 dB; RL ≥ 18.0 dB; NEXT ≥ 39.8 dB; PS NEXT ≥ 37.8 dB; EL FEXT ≥ 21.8 dB; PS EL FEXT ≥ 18.8 dB; Phase delay ≤ 537 ns
- Test at 250 MHz (100 m)
- ATT ≤ 32.85 dB; RL ≥ 17.3 dB; NEXT ≥ 38.3 dB; PS NEXT ≥ 36.3 dB; EL FEXT ≥ 19.8 dB; PS EL FEXT ≥ 16.8 dB; Phase delay ≤ 536 ns
Selection notes
- The documented specifications apply to the cited manufacturer version. Confirm the supplied hardware, firmware and accessory configuration.
- Test lengths and electrical limits are source conditions, not an unconditional installation guarantee. Confirm route, connectors, required fire rating and actual supplied roll.
- Readers, locks, power supplies, batteries, licences and other accessories are not assumed to be included. ISD confirms specification, compatibility, supply, price, lead time and local warranty separately.
Official documents
Manufacturer source checked 2026-09-10. The supplied unit and local terms require confirmation.
IS DistributionsEnquire