DS-3E1526P-SI
The Hikvision DS-3E1526P-SI is documented as a smart-managed 24-port Gigabit PoE switch with two separate Gigabit SFP fibre ports. Compare the connected-device load against the documented total PoE budget, check the input power and management requirements, then keep the full model and choose quantity for an ISD supply enquiry.
Hikvision · Full reference: DS-3E1526P-SI
Choose quantityManufacturer reference
Manufacturer details describe the cited version. Confirm the exact unit and intended system.
Product reference
- Device class
- Smart Managed 24-Port Gigabit PoE Switch
Ports and PoE
- Port layout
- 24 Gigabit PoE RJ45 ports numbered 1 to 24, plus 2 Gigabit SFP fibre-optical ports numbered 25 and 26 as documented. These are separate labelled interfaces; no additional copper or combo ports are inferred. Optical modules are not assumed included.
- Copper port reference
- RJ45, full duplex and MDI/MDI-X adaptive as listed in the Port Type row. Confirm cable and link requirements; this row does not specify an optical-module type.
- Ethernet standards
- IEEE 802.3, IEEE 802.3u, IEEE 802.3x, IEEE 802.3ab and IEEE 802.3z as listed. Confirm the actual interface and connected equipment.
- PoE standards
- IEEE 802.3af and IEEE 802.3at as listed for the PoE ports. Confirm powered-device compatibility and load; no IEEE 802.3bt or higher-power sibling capability is inferred.
- PoE port power
- Ports 1 to 24: maximum 30 W per port as listed. This does not mean all ports can supply 30 W simultaneously; the total PoE budget and load conditions also apply.
- Total PoE budget
- 370 W as listed for total PoE output. This is not the input-power rating or a sum of every port maximum. Confirm the complete device load and operating conditions.
- PoE control
- PoE watchdog on ports 1 to 24 is documented to detect and restart cameras that do not respond; PoE enabling is supported. Confirm configuration and device behaviour; a restart may interrupt service and is not a fault-prevention guarantee.
Switching and performance
- Forwarding method
- Store-and-forward switching as listed. Actual application throughput depends on the network and configuration.
- Operating modes
- Standard mode (default) and Extend mode are listed. Confirm the required mode and its operating conditions; this entry does not establish an extended-distance speed.
- MAC address table
- 8 K as listed. This is a MAC-table reference, not a concurrent-customer or user limit.
- Internal cache
- 4.1 Mbits as listed. The source uses bits, not megabytes.
Management and traffic
- Maintenance functions
- Remote upgrade, default-parameter recovery, log viewing, basic network-parameter configuration, configuration import/export and time synchronisation are listed. Confirm firmware and supported management tools; this does not approve any upgrade or current patch level.
- Port configuration
- Port-rate configuration, flow control and port enabling as listed. Confirm the required settings for the connected equipment.
- Port rate limiting
- Ingress and egress port rate limiting as listed. No rate granularity or traffic guarantee is inferred.
- Storm control
- Unknown-unicast, multicast and broadcast storm control as listed. Configure and test against the actual network.
- Port mirroring
- Port mirroring is listed as supported. Confirm the available session and port configuration; no session count is inferred.
- Link aggregation
- Static link aggregation is listed. This is not evidence of LACP support or universal aggregation interoperability.
- Port isolation
- Ports in an isolation group cannot communicate with each other, as documented. Confirm the configured group and intended access paths.
- QoS reference
- WRR and SP scheduling and port priority as listed. Confirm configuration; no application-service guarantee is inferred.
- VLAN reference
- 4094 VLANs as listed. This is the document VLAN entry, not a number of users or an assumption about the site VLAN configuration.
- Spanning tree
- STP and RSTP protocols as listed. Confirm the actual topology and supported configuration; no MSTP feature is inferred.
- SNMP reference
- SNMPv1 and SNMPv2c are listed for obtaining system and interface node information. This historical entry is not a current security approval or a recommendation for Internet exposure; confirm secure site management and firmware.
- LLDP reference
- LLDP is listed for port configuration, global configuration and neighbor discovery. Confirm the management platform and network settings.
- Topology and monitoring
- Network topology management, alarm push and network-health monitoring are listed. Confirm the supported Hikvision software platform, firmware, permissions and any licence requirements; no cloud service or message delivery is assumed enabled.
Construction and environment
- Housing material
- Metal material as listed. No outdoor or ingress-protection rating is established by the housing entry.
- Weight reference
- Net weight: 2.975 kg (6.56 lb); gross weight: 3.535 kg (7.79 lb) as separately listed. Confirm the exact supplied unit and actual package; net and gross weight are not interchangeable.
- Dimensions
- W × H × D: 440 × 44 × 221 mm (17.32 × 1.73 × 8.7 in) as listed. The p4 drawing shows the same three overall dimensions. Confirm installation clearances and the exact supplied unit.
- Storage temperature
- -40 °C to 85 °C (-40 °F to 185 °F) as listed. Storage limits are not operating limits.
- Humidity
- Operating humidity and the separately labelled Relative Humidity entry both list 5% to 95%, no condensation. Confirm site conditions; no weatherproof rating is inferred.
Power and protection
- Maximum consumption
- 400 W as listed for maximum power consumption. This is not a PoE output budget; retain the separate input and output figures when checking the design.
- Idle consumption
- 30 W as listed for power consumption in idle. This is not PoE power available to connected devices or a full-load figure.
- Surge reference
- 6 kV surge protection for PoE ports is stated on the cover. This does not establish the same rating for every interface, a site lightning-protection design or a no-damage guarantee.
- Physical indicator reference
- The interface drawing labels PWR, PoE-MAX, LINK/ACT and PoE indicators, with separate LINK/ACT labels for optical ports 25 and 26. Confirm indicator meanings in the supplied-unit instructions; no threshold or alarm behaviour is inferred.
Selection notes
- This reference concerns DS-3E1526P-SI only. Confirm the exact supplied hardware, firmware, powered devices, optics, cabling, configuration and package with ISD; EI, /M, V2 and other SI port-count variants are not interchangeable.
- ISD supplies products only. Confirm stock, price, ETA, adapter or power lead, optical modules, actual package and local warranty. An enquiry is not an order, payment or stock reservation.
- Each port limit, total PoE output budget, input rating, maximum consumption and idle consumption are different figures. Check the complete connected load and operating conditions before selection.
- Confirm management-platform, firmware, licence and network settings before use. Historical management protocols are not a current security assessment or advice to expose the switch to the Internet.
- Extended-distance operation needs the exact supported speed, cable, load and mode confirmed. No distance-performance guarantee is made here. Application drawings do not establish universal compatibility or included cameras, intercoms, gateways, optics or software.
Official documents
Manufacturer source checked 2026-10-18. The supplied unit and local terms require confirmation.
IS DistributionsEnquire