DS-3T1506HP-EI-UPS

Hikvision DS-3T1506HP-EI-UPS is a 4-Port Gigabit Smart Managed Industrial Solar PoE Switch. Its total PoE budget is 110 W with 54 VDC input or 60 W with 12–24 VDC solar/battery input. Ports 3 and 4 offer selectable passive PoE, and the RS485 interface is reserved for battery monitoring.

Hikvision · Full reference: DS-3T1506HP-EI-UPS

Choose quantity

Manufacturer reference

Manufacturer details describe the cited version. Confirm the exact unit and intended system.

General

Net Weight
0.7 kg (1.54 lb)
Gross Weight
1.16 kg (2.56 lb)
Dimensions (W × H × D)
158.00 mm × 44.00 mm × 130.00 mm
Operating Temperature
-40 °C to 75 °C (-40 °F to 167 °F)
Storage Temperature
-40 °C to 85 °C (-40 °F to 185 °F)
Operating Humidity
5% to 95% (no condensation)
Relative Humidity
5% to 95% (no condensation)
Power Supply
12 V DC, 10 A or 24 V DC, 5 A; 54 V 2.22 A
Installation Mode
Desk-Mounted, Rail, Wall-Mounted
Max. Power Consumption
120 W
Power Consumption in Idle
2 W
Surge Protection
6 kV
Shell
Metal material, IP30

Network Parameters

Ports
4 × Gigabit PoE port,2 × Gigabit fiber optical port,1 x RS485 port
MAC Address Table
2 K
Switching Capacity
Whole-Device Performance: 14 Gbps Port Performance: 12 Gbps
Packet Forwarding Rate
Whole-Device Performance: 10.42 Mpps Port Performance: 8.93 Mpps
Internal Cache
1 Mbits

PoE Power Supply

PoE Standard
Port 1: IEEE 802.3af, IEEE 802.3at, IEEE 802.3bt Ports 2 to 4: IEEE 802.3af, IEEE 802.3at Ports 3 to 4: support passive PoE, 24 V or 54 V output depending on DIP switch settings
PoE Power Pin
Port 1: 8-pin power: 1/2(-), 3/6(+), 4/5(+), 7/8(-) Port 2: End-span: 1/2(-), 3/6(+) Ports 3 to 4: 8-pin power: 1/2(-), 3/6(+), 54 V output ; 4/5(+), 7/8(-), 24 V output
PoE Port
Hi-PoE: Port 1 PoE: Ports 2 to 4
Max. Port Power
Port 1: 90 W Ports 2 to 4: 30 W
PoE Power Budget
DC 54 V input: 110 W; DC 12 V–24 V input: 60 W

Software Function

Long Range
Ports 1 to 4: up to 300 m. Long range performance may vary depend on camera model or cable condition.
Port Isolation
Ports 1 to 6: port isolation mode to improve network security Ports in an isolation group cannot communicate with each other, but they can communicate with ports outside the isolation group.
PoE Watchdog
Ports 1 to 4: auto detect and restart the cameras that do not respond.
Link Aggregation
Link aggregation is used to aggregate multiple physical ports to form a logical port for load balancing, bandwidth expansion, and port protection. Support static link aggregation. Support 2 aggregation group(s).
Loop Prevention
Loop prevention is used to prevent the switching network from forming loops, which will seriously affect network communication. Disabled by default. Support 802.1D STP. Support 802.1w RSTP. Support G.8032 ERPS.
VLAN
VLAN is used for network scale planning and network health improvement. Support 802.1Q. Configurable VLAN ID from 1-4094. Support Trunk, Access port mode. Support Max. 4094 VLAN.
HPP
Support one-click activation and remote management via Hik-Partner Pro. Functions supported: 1. Display the port rate. 2. Display the port bandwidth utilization rate. 3. Display the PoE power usage. 4. Display topology information. 5. Display the alarm status. 6. Restart ports and devices. 7. Enable port long-rage mode. 8. Remotely upgrade the device.
System Maintenance
Support device management via web. Support DHCP Client. Enabled by default for dynamic assignment of management IP addresses. Support Super IP, which is a fixed IP address (10.180.190.200) for direct access. Support management via Hik-Central Pro. Support remote management via Hik-Partner Pro. Support cable detection. Abnormal open circuits and short circuits as well as network cable length can be detected. Support 802.1ab LLDP for peer device discovery. Support port mirroring for fault locating.
DHCP Snooping
DHCP Snooping can prevent unauthorized connections to DHCP servers from disrupting the network and affecting normal network communication, and only allow DHCP packets from trusted ports to pass through. Disabled by default.
DDM (Digital Diagnostic Monitoring)
Support real-time monitoring of key parameters in optical modules, such as operating temperature, operating voltage, operating current, and Rx and Tx optical power.

Approval

EMC
CE-EMC (EN 55032: 2015+A11: 2020, EN IEC 61000-3-2: 2019, EN 61000-3-3: 2013+A1: 2019, EN 50130-4: 2011+A1: 2014, EN 55035: 2017+A11: 2020), IC (ICES-003: Issue 7:2020), RCM (AS/NZS CISPR 32: 2015)
Safety
CB (AMD1:2009, AMD2:2013, IEC 62368-1: 2014 (Second Edition)), CE-LVD (EN 62368- 1: 2014+A11: 2017)
Chemistry
CE-RoHS (2011/65/EU), WEEE (2012/19/EU), Reach (Regulation (EC) No.1907/2006)

Physical Interface

Power Input Connections
Select DC 54 V for normal power input or DC 12-24 V for solar power input as required. • DC 54 V: Use a self-prepared power cord and power adapter to connect the switch to a power socket. • DC 12-24 V: Use two self-prepared power cords to connect the DC positive electrode to the battery positive electrode and the DC negative electrode to the battery negative electrode respectively.
DIP Switch Settings
1 (24 V/54 V for port 3): • When the DIP switch 1 is set to Port3 24V, port 3 can be compatible with 24 V forced PoE powered devices, such as wireless bridges. • When the DIP switch 1 is set to 54V, port 3 only supplies power to IEEE 802.3af/at PoE powered devices, such as IPCs. 2 (24 V/54 V for port 4): • When the DIP switch 2 is set to Port4 24V, port 4 can be compatible with 24 V forced PoE powered devices, such as wireless bridges. • When the DIP switch 2 is set to 54V, port 4 only supplies power to IEEE 802.3af/at PoE powered devices, such as IPCs. 3 (All indicators off/on): • When the DIP switch 3 is set to ALL LED OFF, all indicators on the switch except the PWR indicator are unlit to save power. • When the DIP switch 3 is set to ON, all indicators on the switch are solid on.
RS485 Battery Monitoring
Reserved for the switch to acquire battery information, such as battery voltage, current, state of charge (SOC), etc.

Selection notes

  • The documented specifications apply to the cited manufacturer version. Confirm the supplied hardware, firmware and accessory configuration.
  • Per-port power, total PoE budget and device consumption are separate manufacturer ratings. Optional SFP modules and power supplies are not presumed included. Only source-confirmed original model/configuration values are included. No omitted suffix, hardware revision, regional order code, kit component, image or price is invented.
  • Readers, locks, power supplies, batteries, licences and other accessories are not assumed to be included. ISD confirms specification, compatibility, supply, price, lead time and local warranty separately.

Official documents

Manufacturer source checked 2026-09-10. The supplied unit and local terms require confirmation.

Continue browsing